[1]孙霄,陶英群,杨兴旺,等.脑深部电刺激术同期植入两侧电极精度的对比研究[J].临床神经外科杂志,2019,16(3):190-193.[doi:10.3969/j.issn.1672-7770.2019.03.002]
 SUN Xiao,TAO Ying-qun,YANG Xing-wang,et al.Comparative study on accuracy of simultaneous bilateral electrodes implantation in DBS[J].Journal of Clinical Neurosurgery,2019,16(3):190-193.[doi:10.3969/j.issn.1672-7770.2019.03.002]
点击复制

脑深部电刺激术同期植入两侧电极精度的对比研究()
分享到:

《临床神经外科杂志》[ISSN:1672-7770/CN:32-1727/R]

卷:
16
期数:
2019年第3期
页码:
190-193
栏目:
神经调控专题
出版日期:
2019-06-15

文章信息/Info

Title:
Comparative study on accuracy of simultaneous bilateral electrodes implantation in DBS
作者:
孙霄陶英群杨兴旺王宇徐梦婷刘阳王诗邈袁立佳王婷婷潘赫
110016 沈阳,解放军北部战区总医院神经外科
Author(s):
SUN Xiao TAO Ying-qun YANG Xing-wang et al.
Department of Neurosurgery, General Hospital of Northern Theater Command,Shenyang 110016, China
关键词:
脑深部电刺激机器人电极精度延期植入
Keywords:
deep brain stimulation robot electrode accuracy delayed implantation
分类号:
R454.1
DOI:
10.3969/j.issn.1672-7770.2019.03.002
文献标志码:
A
摘要:
【摘要】目的 探讨脑深部电刺激(DBS)术同期植入两侧电极的精度差异。方法收集北部战区总医院神经外科2017年2月—2019年2月行同期双侧DBS术患者133例。在ROSA机器人辅助下共植入电极266侧,其中丘脑底核(STN)160侧、丘脑腹中间核(nucleus ventralis intermedius,Vim)2侧、苍白球内侧部(Gpi)104侧。所有患者均于术后2 h和术后1周复查头部CT三维重建,并与术前CT图像(手术计划靶点)融合;测量植入电极与计划靶点在靶点平面X轴和Y轴上的误差距离。结果全部266根治疗电极均成功植入,未发生颅内出血、颅内感染和偏瘫等严重并发症,也未出现电极折断现象。术后2 h和术后1周时,第一侧与第二侧植入电极在X轴与Y轴上的误差比较,差异均无统计学意义(均P>0.05)。结论ROSA机器人辅助下DBS术同期植入两侧电极的精度无明显差异。DBS术可以同时植入双侧治疗电极,无需延期手术植入第二侧电极。
Abstract:
Abstract: ObjectiveTo compare the accuracy of simultaneous implantated bilateral electrodes in deep brain stimulation(DBS). Methods133 patients with bilateral DBS from February 2017 to February 2019 in the department of neurosurgery, the General Hospital of Northen Theater Command were included. A total of 266 electrodes were implanted, including 160 sides of subthalamic nucleus(STN), 2 sides of ventromedial nucleus of thalamus and 104 sides of globus pallidus interior(Gpi). All patients underwent three-dimensional reconstruction of the head 2 hours after operation and 1 week after operation, which was fused with the preoperative surgical plan.The distance between the implanted electrode and the preoperative target on the X and Y axes in the target plane was measured. ResultsAll 266 electrodes were successfully implanted, and no serious complications such as intracranial hemorrhage, intracranial infection and hemiplegia occurred, and no electrode fracture occurred.There was no statistically significant difference in the error(all P>0.05), between the first implanted electrode and the second implanted electrode on the X-axis and the Y-axis, neither at 2 hours postoperatively nor 1 week after surgery. ConclusionDBS can accurately implant both electrodes at the same time without delaying the implantation of the second electrode.

相似文献/References:

[1]张宇清,李建宇,李继平,等.运动障碍病脑深部电刺激手术并发症分析[J].临床神经外科杂志,2016,(01):31.
[2]吴曦.脚桥核的功能和临床应用研究进展[J].临床神经外科杂志,2014,(04):315.
[3]徐欣,凌至培,余新光,等.多通道微电极记录在帕金森病脑深部电刺激定位中的作用[J].临床神经外科杂志,2016,(06):401.
 XU Xin,LING Zhi-pei,YU Xin-guang,et al.Role of multichannel microelectrode recording on location of lead implants for deep brain stimulation[J].Journal of Clinical Neurosurgery,2016,(3):401.
[4]李建宇,任志伟,郭松,等.大脑脚间核脑深部电刺激改善帕金森病冻结步态的效果[J].临床神经外科杂志,2017,14(05):382.
 LI Jian-yu,REN Zhi-wei,GUO Song,et al.Pedunculopontine nucleus stimulation improves gait freezing in parkinson disease[J].Journal of Clinical Neurosurgery,2017,14(3):382.
[5]张世航,王家莉,吴曦,等.脑深部电刺激术对帕金森病短期静态姿势平衡稳定性的影响[J].临床神经外科杂志,2018,15(02):85.
 ZHANG Shi-hang,WANG Jia-li,WU Xi,et al.Effect of deep brain stimulation on static posture balance in Parkinsons disease[J].Journal of Clinical Neurosurgery,2018,15(3):85.
[6]朱冠宇,陈颍川,王秀,等.震颤起病与非震颤起病的帕金森病脑结构差异与脑深部电刺激的预后差异分析[J].临床神经外科杂志,2019,16(3):185.[doi:10.3969/j.issn.1672-7770.2019.03.001]
 ZHU Guan-yu,CHEN Ying-chuan,WANG Xiu,et al.Structural difference of tremor onset and non-tremor onset in Parkinson disease patients and prognosis of two groups[J].Journal of Clinical Neurosurgery,2019,16(3):185.[doi:10.3969/j.issn.1672-7770.2019.03.001]
[7]李建宇,任志伟,郭松,等.脑深部电刺激苍白球内侧部和丘脑底核对帕金森病震颤改善的对比性研究[J].临床神经外科杂志,2019,16(3):199.[doi:10.3969/j.issn.1672-7770.2019.03.004]
 LI Jian-yu,REN Zhi-wei,GUO Song,et al.STN vs. GPi deep brain stimulation for tremor suppression in Parkinson disease[J].Journal of Clinical Neurosurgery,2019,16(3):199.[doi:10.3969/j.issn.1672-7770.2019.03.004]
[8]邱畅,董文文,章文斌.立体定向框架下帕金森病脑深部电刺激手术标准化流程的思考与改进[J].临床神经外科杂志,2019,16(3):203.[doi:10.3969/j.issn.1672-7770.2019.03.005]
 QIU Chang,DONG Wen-wen,ZHANG Wen-bin..Analysis and optimization of standardized procedure for deep brain stimulation in Parkinson’s disease using stereotactic framework[J].Journal of Clinical Neurosurgery,2019,16(3):203.[doi:10.3969/j.issn.1672-7770.2019.03.005]
[9]党圆圆,李勇,杨艺,等.植物状态患者脑深部电刺激术后脑脓肿1例报告并文献复习[J].临床神经外科杂志,2019,16(3):219.[doi:10.3969/j.issn.1672-7770.2019.03.008]
 DANG Yuan-yuan,LI Yong,YANG Yi,et al.Brain abscess after deep brain stimulation in patients with vegetative state(report of 1 case and review of literature)[J].Journal of Clinical Neurosurgery,2019,16(3):219.[doi:10.3969/j.issn.1672-7770.2019.03.008]

更新日期/Last Update: 2019-06-15